List of common fault codes of Tongyi air energy water heater

Views : 422
Author : Silence
Update time : 2022-03-02 15:23:58
         List of common fault codes of Tongyi air energy water heater
show code Fault conditions cause of issue Method of exclusion
E01 water temperature
sensor failure
Water temperature sensor open or short circuit Check the water temperature sensor cable
or replace the water temperature sensor
E02 ambient temperature
sensor failure
Ambient temperature sensor is open or shorted Check the ambient temperature sensor cable
or replace the ambient temperature sensor
E03 System 1 Coil Temperature sensor failure Coil temperature sensor open or short circuit Check coil temperature sensor wiring
or replace the coil temperature sensor
E04 Water flow switch protection Fault Water flow switch disconnected
water line clogged
Water pump does not start
Insufficient water flow
Check or replace the water flow switch
Cleaning water pipes and filters
Check or replace high flow water pump
E05 System 1 high voltage protection fault  High voltage protection disconnected
Insufficient water flow
Cleaning water pipes and filters
Check or replace the high voltage protector
E06 System 1 low voltage protection fault Low voltage protection disconnected
Insufficient refrigerant in the system
Supplementary refrigerant
Check or replace the low voltage protector
E07 Outlet temperature
sensor failure
The outlet water temperature sensor is open or shorted Check the connection wire of the outlet water temperature sensor
Or replace the outlet water temperature sensor
E08 water level
Water shortage protection fault
Water tank shortage
water level line break
Check or clean water supply pipes and water supply valves
Check water level and reposition
E09 Insufficient water flow
Temperature difference protection fault
The temperature difference between inlet and outlet is too large
Insufficient water flow
Cleaning water pipes and filters
Check or replace high flow water pump
E10 Operation communication failure Poor contact or open circuit of the operation panel connection line Check the operation panel connection
Replacing the operation panel or main board
E11 System 2 Coil Temperature
sensor failure
Coil temperature sensor open or short circuit Check coil temperature sensor wiring
or replace the coil temperature sensor
E12 System 2 high voltage protection fault High voltage protection disconnected
Insufficient water flow
Cleaning water pipes and filters
Check or replace the high voltage protector
E13 System 2 low voltage protection fault Low voltage protection disconnected
Insufficient refrigerant in the system
Supplementary refrigerant
Check or replace the low voltage protector
E14 System 1 exhaust high temperature protection fault Exhaust temperature is too high
Insufficient refrigerant
Replenish refrigerant or adjust throttle valve
Replacing the Press Lubricant
E15 System 2 exhaust high temperature protection fault Exhaust temperature is too high
Insufficient refrigerant
Replenish refrigerant or adjust throttle valve
Replacing the Press Lubricant
E16 System 1 Exhaust Temperature
sensor failure
Exhaust temperature sensor open or short circuit Check exhaust temperature sensor wiring
or replace the exhaust temperature sensor
E17 System 2 Exhaust Temperature
sensor failure
Exhaust temperature sensor open or short circuit Check exhaust temperature sensor wiring
or replace the exhaust temperature sensor
E18 Water high temperature protection fault The outlet water temperature of the direct heat circulating unit is too high Increase the inlet water flow or replace the inlet water pump
Supplementary refrigerant
E19 System 1 return air temperature
sensor failure
Return air temperature sensor open or short circuit Check exhaust temperature sensor wiring
or replace the exhaust temperature sensor
E20 System 2 return air temperature Return air temperature sensor open or short circuit Check exhaust temperature sensor wiring
or replace the exhaust temperature sensor