Introducing Tongyi's Holiday Mode

Views : 194
Update time : 2024-04-16 15:13:00

As the summer holiday season approaches, homeowners are often faced with the dilemma of ensuring their HVAC systems operate efficiently while they’re away, without compromising on comfort and safety. Recognizing this challenge, Tongyi is proud to introduce the innovative Holiday Mode, a feature designed to optimize system reliability, conserve energy, and maintain a comfortable indoor environment, even when homeowners are enjoying time away from home.

The Holiday Mode is a multifaceted solution tailored to address the specific needs of homeowners during extended periods of absence. Here’s how it works:

Enhancing System Reliability:

During the winter months, one of the primary concerns for homeowners is the risk of water freezing within their HVAC system. With the Holiday Mode activated, the unit operates in heating mode and/or Domestic Hot Water (DHW) mode with low water temperature settings. This proactive approach helps prevent water from freezing, ensuring the system remains operational and safeguarding against potential damage.

Energy Conservation:

In addition to enhancing reliability, the Holiday Mode is designed to conserve energy without compromising on performance. By operating at low water temperatures during periods of absence, the system reduces energy consumption while still maintaining optimal functionality. This not only contributes to cost savings for homeowners but also promotes environmental sustainability by minimizing energy usage.

Customizable Settings:

Flexibility is key when it comes to meeting the diverse needs of homeowners. With the Holiday Mode, users have the freedom to customize settings according to their preferences and schedule. Whether it’s adjusting the temperature set points or specifying the duration of the holiday period, homeowners can tailor the functionality of the system to align with their lifestyle and travel plans.

Germ-Free Water:

Beyond comfort and energy efficiency, the Holiday Mode offers an additional layer of convenience and peace of mind. Users can pre-set the disinfection mode before their return home, ensuring that germ-free water is readily available for consumption and daily use. This proactive measure underscores Tongyi’s commitment to prioritizing the health and well-being of homeowners, even in their absence.

At Tongyi Heat Pump, we remain dedicated to delivering innovative solutions that redefine the standards of comfort, efficiency, and convenience. Experience the difference with the Holiday Mode and discover a new level of comfort and peace of mind for your home.

Related News
Read More >>
Frost Protection for Your Heat Pump System Frost Protection for Your Heat Pump System
Oct .21.2024
As colder temperatures approach, it’s essential to protect your heat pump system from the risk of freezing. Frost can cause significant damage to the hydraulics, leading to expensive repairs or replacements. The key to preventing this is ensuring that your system’s water circuit is properly protected with antifreeze. Here’s how you can safeguard your system and ensure its longevity during freezing conditions.

Glycol Concentration: The Key to Frost Protection
To prevent freezing, it’s crucial to use a proper weight concentration of glycol based on the lowest expected outdoor temperatures. Refer to the table below to determine the correct concentration of antifreeze for your system.

Minimum outdoor temperature -5℃ -10℃ -15℃ -20℃
Ethylene glycol 10% 15% 20% 25%
However, keep in mind that only one type of antifreeze should be used. Mixing different antifreezes can lead to corrosion and other problems. Always check the concentration of the antifreeze periodically to maintain optimal protection.

Be Aware of System Performance
While antifreeze is effective in preventing frost, it can have side effects on your system. The use of antifreeze may lead to a pressure drop and reduced capability of your heat pump system. Furthermore, when antifreeze is used, corrosion can occur. To mitigate this, ensure that a corrosion inhibitor is added to protect the metal components of your system.

Handling Antifreeze with Care
Antifreeze, especially ethylene glycol, is toxic. The concentrations recommended won’t necessarily prevent freezing but will stop the hydraulics from bursting. Always handle antifreeze with care, making sure to avoid skin contact, and follow all relevant local laws and regulations regarding its usage.

Preventing Corrosion: Tips for a Safe System
One major risk when using glycol-based antifreeze is corrosion. Glycol, especially uninhibited glycol, can turn acidic under the influence of oxygen, copper, and higher temperatures, accelerating the corrosion of metal surfaces. Here are some tips to ensure your system stays corrosion-free:

Select glycol with corrosion inhibitors to counteract acids formed by glycol oxidation.
In systems with a domestic hot water tank, use propylene glycol, as it’s safer for water heating purposes. For other installations, ethylene glycol is permitted.
Avoid automotive glycol because its corrosion inhibitors have a limited lifespan and may contain silicates, which can foul or block your system.
Do not use galvanized piping in glycol systems, as it can lead to chemical reactions with the corrosion inhibitors.
Ensure the glycol is compatible with the materials used in your system to avoid potential issues.
Trust the Experts for Water Treatment
It is crucial to have the water in your system treated by a qualified specialist. They will ensure that the water treatment is correctly performed, minimizing the risk of corrosion and maintaining the efficiency of your heat pump system.